NetShelter VX PDF Brochure

NetShelter VX Enclosures
Next generation, high quality enclosure solutions designed to meet the needs of today’s and tomorrow’s networking environment.

The NetShelter VX is APC's next generation enclosure solution. NetShelter VX addresses many of the emerging trends and issues datacenter managers face today by incorporating new features and benefits that allow customers to create a more effective datacenter environment. Increasing server depths combined with the requirement for more effective cable management and power distribution has led to a need for deeper enclosures. Increasing power densities have led to a need for enclosures that provide superior ventilation. Varying datacenter requirements have led to a need for a more robust offering of enclosure sizes and options. The desire for quick deployment of datacenter solutions has led to a need for enclosure solutions that are easy to use and install. NetShelter VX enclosures have been designed with all of these trends in mind.

 

Features & Benefits
 
Compatibility
 
Door ventilation exceeds 830 in2 (5355 cm2) Adequate ventilation is required for proper operation of today's servers. NetShelter VX and VS Enclosures include fully perforated front and rear doors to provide ample ventilation for servers and networking equipment. The perforation pattern provides 844 square inches of open area on the front door, exceeding requirements set forth by major server manaufacturers. Although this ventilation pattern provides adequate cooling for most configurations, air-moving accessories such as APC's Air Distribution Unit are also available to support higher heat density applications.
Adjustable mounting depth Vertical mounting rails are adjustable for equipment with various mounting depths.
Guaranteed Compatability Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. APC's "Fits Like a Glove" money back guarantee provides peace of mind that all of your EIA-310-D compliant rack-mount equipment will physically fit in a NetShelter VX enclosure.
Ventilated Doors with Scalable Cooling Options Superior door ventilation exceeds airflow requirements for major servers. Scalable cooling options for high-density applications.
 
Convenience
 
Rear Cable Management channels Integrated rear cable management channels allow customers to easily route, manage, and access large numbers of data cables even while an enclosure is loaded with rack-mount equipment and bayed within a row.
Rear Power Distribution channels Rear power distribution channels provide easy access to multiple receptacles occupying zero U in recessed channels . The rear power distribution channels allow APC basic, metered, and switched vertical rack PDU's to be installed easily in the rear without interfering with equipment or taking up valuable U space. This provides increased accessibility to receptacles and allows customers to support more power cords within the enclosure. Up to 42 5-15R receptacles can be installed in just one rear cabling channel.
Cable Access APC understands that power and data can be routed either from overhead or from underneath a raised floor. Generous cable access holes are provided in the roof and base. The 42 inch (1070 mm) deep versions provide two 4x8 inch (102x203 mm) cable access holes in the roof directly above the rear cabling channels and two 4x4 inch (102x102 mm) cable access holes directly below the rear cabling channels to provide cable access where it is really needed. On occasion, a power or data cable may need to be routed to an adjacent enclosure when two or more enclosures are bayed together. The 42 inch (1070 mm) deep versions provide side cable pass through holes in the rear cabling channels to allow for such requirements.
Numbered U positions Rapid installation of rack mounted equipment.
Optimized depth Enclosures deeper than those traditionally used are required to properly install the latest servers, distribute power, and manage cabling in today's data centers. The struggle facing data center managers is determining how deep to go without sacrificing valuable floor space. In a hot aisle/cold aisle layout NetShelter VX Enclosures provide the maximum enclosure depth (42 inches (107 cm)) without sacrificing floor space. This allows for 36 inches (91 cm) of clearance in the hot aisle and 48 inches (122 cm) in the cold aisle. In a hot aisle/cold aisle layout, selecting enclosures less than 42 inches (107 cm) deep will not allow more enclosures to be installed in a datacenter, but only increase the clearance in the hot aisle.
Optimized width NetShelter VX Enclosures are designed to align exactly on standard 24 inch and 600 mm wide floor tiles when bayed together.
Rolls through a 7 foot doorway APC has made installation fast and easy by designing the enclosure such that it rolls through standard 7 foot doorways. This feature does not apply to 47U versions.
Ships fully assembled NetShelter VX Enclosures ship fully assembled reducing the time required to install equipment.
Simple Selection No need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. APC has made it easy by handling the details and providing complete enclosures with single part numbers.
 
Protection
 
Lockable doors and side panels Increased level of security to prevent unauthorized entry. Front doors, rear doors, and side panels are lockable and only accessible with a key provided with NetShelter Enclosures.
Door access monitoring An optional door alarm switch kit (APC part # AP9513) combined with an APC Environment Monitoring Unit (APC part # AP9312TH or AP9312THI) permits access monitoring of NetShelter VX enclosures. It is possible to be notified via e-mail, pager, or SNMP if an enclosure door has been opened.
Structural Stability A proven frame design, heavy gauge mounting rails, and heavy-duty casters provide for 2000 lb (909 kg) static and dynamic load ratings.
Shipping Pallet All NetShelter VX Enclosures are shipped on a robust, shock absorbing pallet designed to support up to 1000 lbs.
 
Safety
 
UBC Zone 4 Compliant NetShelter VX Enclosures are UBC (Uniform Building Code) Zone 4 compliant if used in conjunction with APC's bolt down bracket kit (part # AR8112BLK).
Protective grounding provisions Safety protection against electric shock and reduction of EMI emissions. NetShelter VX Enclosures incorporate a series of ground studs within each enclosure, providing adequate means for grounding all loose sheet metal panels and/or internally rack-mounted equipment.
 
Serviceability
 
Quick release doors During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the enclosure doors. Quick release hinge pins allow for fast, easy access.
Quick release side panels During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the side panels. Quick release slam latches on the side panels allow for quick, easy access.
Split rear doors Split rear doors improve access and serviceability to rear of rack mounted equipment. The split rear doors help to maximize floor space. Only 11 inches (279 mm) of clearance is required behind the enclosures to allow for door swing.
 
Adaptability
 
Reversible doors In situations where it is desirable for the front door to open from the opposite side, doors can be detached and reversed.
Expansion VX and VS Enclosures can be easily expanded upon to create complete rows of enclosures. Enclosures models that ship without side panels include hardware required to bolt to adjacent enclosures.

 

APC Copyright Notice

CALL 972-484-8151 or Toll Free 888-566-1615

Email Us at Pro@LEDpowerPRO For Assistance

 

Contact Us   |   About LED Enterprises, Inc.   |   Search   |

Send mail to powerpro@ledpowerpro.com with questions or comments about Power Quality Products, Services, or this web site.
Copyright © 2001 LED Enterprises, Inc.
  Privacy Notice      Conditions of Use